cable glands PG 16/13,5 ZK 3 … %PDF-1.6 %���� light switch clipart. MDR 1: MDR 1 is a single-phase, 2-pole switch offered for either air pressure or water pressure. Condor Air Compressor Type pressure switch with on/off switch and unloader valve with 6mm push fit tube connection. The Condor MDR2 pressure switch can be used for single phase compressors or as a pressure switch to provide a signal to the control circuit in a larger compressor. pin. Applications. cut-out pressure 35 bar 3-pole (N.C.) Acc. Pressure relief valve Pressure Switches – Factory Air Compressor Parts COLEMAN SANBORN 034-0133 PRESSURE SWITCH 95-125 PSI AIR COMPRESSOR PART: pin. Control pressure switches. For maximum performance, compressors must be adjusted properly. • Scale for simple adjustments • Wide range of variations • Acc. The MDR2 has built in adjustable differential capability to have greater control over the cut out pressure of the switch. www.condor-cpc.com 27 Pressure Diagrams MDR 1 Cable glands MDR 1 Pressure switch MDR 1 WN PG 11 G PG 11 Z PG 11 ZK Explanation Devices without differential pressure adjustment After selecting the cut-in pressure, the cut-out pressure can be read from the pressure diagram. Let us help you find a replacement pressure switch or an industrial pressure … Condor USA is a subsidiary of Condor-Werke GmbH, a pressure control pioneer founded in 1893. ENQUIRE NOW : Condor 3 pole pressure switch 10 bar (150 psi) 690v. Example: MDR 1/11 with differential pressure adjustment With a preselected cut-in pressure of 4 bar, the cut-out pressure can be determined and set between 5.4 and 8 bar using the differential pressure adjustment. Recently the plastic button controlling the pressure switch broke. h޼Y�n�8~����šJ") Xpܦ�k����wIpPl&�,���M��of()r'v�;4 �3C��D:�B�؈ q,�1��S�P$Ri"�@�)�BQ-:�E�Di#-� +�a"�E$���(IQ.�QF�T This 1 Phase Pressure Switch is Fully Adjustable suitable for compressor.. to EN 60947; KEMA-EUR • Differential adjustment (standard equipment) • Flange = Die-cast aluminium . Pneumatic nail guns, for example, won't drive nails to the correct depth unless the air compressor is correctly adjusted. Adjustments are to be carried out only when the switch is mounted, under pressure and. Acc. Control pressure switches Condor USA, Inc Pressure Switch, Dpst, 100/125 Psi, Stndard 5.0 out of 5 stars 1 Condor USA, INC Air Compressor Pressure Switch; Range: 25 to 160 psi, Port Type: (4) Port, 1/4" FNPT cut-out pressure 35 bar 3-pole (N.C.) Acc. These two values can be adjusted on the pressure switch MDR 5/5. Many carpentry and mechanical jobs require air compressors. to EN 60947 ... Condor USA, Inc. Scharco Elektronik GmbH. MDR 21 Condor Pressure Switch, style. On/Off Switch on top; Some Condor Pressure Switches bottom unloader valves. Installing the DPA - circuit board onto MDR 3, the pressure switch offers the following additional functions: • Phase sequence control • Phase failure detection • Supervision of an external opener possible, e. g. Klixon. .�w9�%h�p>��Xδ����$�C�XY�4#?0 B (� When carrying out a differential pressure adjustment on the pressure switch types MDR 1, MDR 11, MDR 2 and MDR 21 the cut-out pressure value changes and the cut-in pressure … • Differential adjustment (standard equipment) ... Pressure switch MDR 11 / 11, Compressor version • Single phase • Switching capacity 4.0 kW / 4 HP • Max. to EN 60947 UL / CSA-approval Type overview MDR 3 Order reference ON / OFF Rotary knob Pressure range POFF in bar Flange Weight in g Part No. • Max. condor mdr 11 pressure switch adjustment. Pressure ranges from 2,5 – 11 bar for the air model, and 2,5 – 6 bar for the water model. Max. Price: $‎277.00 (Excl. Electronic Components. Pressure switch MDR 21 • Single phase • Switching capacity 2.2 kW / 3 HP • Max. Page 3.14 www.condor-cpc.com Pressure switch MDR 3 3-phase Switching capacity 7.5 (11) kW Available with overload relay Max. 4 Port. Order reference: ON / OFF Rotary knob: cable glands PG13,5 Z/ZK • With delayed unloader valve AEV 11 S ... www.Condor-Werke.com 6mm 90 0 unloader – Slow pressure release device. ENQUIRE NOW : Condor 3 pole pressure switch 10 bar (150 psi) 690v. IP44 (when mounted vertical. ... Condor MDR 21 MDR 21 Condor Pressure Switch - Master Tool Repair MDR 21 - MDR 21 Condor Pressure Switch: pin. Condor information videos Video - Pressure switch settings Mdr-5/8 Pressure switches-information on you will find instructions for pressure adjustment as well as other information videos - Qr-Code. If only the cut-out pressure is known, the cut-in pressure to be set ... Condor MDR 21 MDR 21 Condor Pressure Switch - Master Tool Repair MDR 21 - MDR 21 Condor Pressure Switch: pin. I have a Campbell Hausfeld Air Compressor (3.5HP, 11 gallon) made in 1996. Max. German Condor MDR2 Pressure Switch. Adjust Condor Air Compressor Pressure Switch , Find Complete Details about Adjust Condor Air Compressor Pressure Switch,Condor Air Compressor Pressure Switch,Condor Pressure Switch,Adjust Air Compressor Pressure Switch from Pressure Switches Supplier or Manufacturer-Yueqing Fubang Industrial Co., Ltd. h�b``b``������ńA�X؀�c�Q���0�TC7�&/���a � V �,_���*��E��Y�x����‡H�3�F��A�``����%,�p�aR�~6�&�#�,M High performance pressure switches. The Condor MDR2 pressure switches are the world’s most famous brand and are used to regulate the tank pressure between two preset values on small (up to 175psi) electrically driven air compressors. ... Let us help you find or customize the appropriate switch. to EN 60947; Flange = Die-cast aluminium; Part No. 4 Electrical terminals6. Navigation Condor information videos Video - Pressure switch settings Mdr-5/8 Pressure switches-information GST) In stock Normally in stock. cut-out pressure 11 bar / 160 psi • Incl. Looking for CONDOR USA, INC Air Compressor Pressure Switch; Range: 25 to 160 psi, Port Type: (1) Port, 1/4 in FNPT (3EYP4)? But like any tool, knowing how to use and care for a compressor can make the difference between easy use and complete frustration. cable glands PG 11 Z/ZK • and unloader valve AEV 1 S • 2-pole (N.C.) • Acc. Air compressor accessories > Condor pressure switches > Civil. endstream endobj startxref Send a message or speak with a Condor USA representative now. Electronic Components. {9��H �"�p�o��—�ɻ��u��Np�8.Xj�T���a\"^�|���o�HJ8l��MG/‹�.~G��/ ��[�[6�/훢ٿ�$�ݛG�¶��n�E�R��@|C"GY/�duѐ1dQ '�qf�iX�7�c����(@jN Air continuously leaks out of the unloader valve to EN 60947 • UL / CSA-approval optional • Differential adjustment (standard equipment) • Flange = Die-cast aluminium . If only the cut-out pressure is known, the cut-in pressure to be set Industries: Compressors Condor Model MDR-11 (General Model SWP60401U NEW) Pressure Switch Adjustment Procedure www.generalairproducts.com 3 1.800.345. It only leaks while it is pumping, once it eventually reaches pressure and shuts off, or if I manually shut it off, then it behaves normally and does not leak air. I have a Campbell Hausfeld Air Compressor (3.5HP, 11 gallon) made in 1996. values can be set on the pressure switch. 1. In the fixed range switch, there will only be one screw for adjusting air compressor pressure switch. The coordinates of a cut-out pressure of 4 bar and a cut-in pressure of 1 bar intersect at a point P2 which lies outside the shaded pressure range of the diagram. In the photo below, the cover has been removed from the pressure switch. cut-out pressure 12 bar / 175 psi • 2-pole (N.C.) • Acc. In the photo below, the cover has been removed from the pressure switch. GLW MDR-F MDR1 MDR11 MDR3 MDR3 RA/RU MDR4S MDR53 MDR5 Unloader valve Float switch (PSN) The entire process can be divided into two major sections: Setting the cut-in pressure. Description. Although a pressure switch comes in different designs and models, there is a uniform approach to adjusting it. IP44 (when mounted vertical. FREE Shipping. First, let me show you the steps for adjusting the pressure switch in any compressor and then I will tell you about both the fixed range and adjustable range screw arrangements for setting a pressure switch. The MDR2 has built in adjustable differential capability to have greater control over the cut out pressure of the switch. pump shafts 3-phase Switching capacity 5.5 kW Max. cut-out pressure 11 bar / 160 psi • Incl. %%EOF 2-pole Single Phase (N.C.) Def. cut-out pressure 12 bar. Icare data recovery free download . The MDR11 (USA) Pressure switch from Condor USA. 6mm 90 0 unloader – Slow pressure release device. Cut-in pressure is 6.1 bar. values can be set on the pressure switch. Code: 42.211. Code: 42.610. The Condor MDR2 pressure switches are the world’s most famous brand and are used to regulate the tank pressure between two preset values on small (up to 175psi) electrically driven air compressors. Condor switch2. Assuming your new pressure switch is adjustable, some are not, the process of changing the settings will depend on the type of adjustment your new pressure switch has. Price: $‎346.00 (Excl. Unloader valves EV 2 With screw connection for 6 mm plastic or copper discharge tubes 25 200666 EV 2S* With quick-connect for 6 mm plastic discharge tubes 25 200680 Condor 2 pole pressure switch 12 bar (174 psi) 250v. www.condor-cpc.com 37 Pressure switch MDR 3 Pressure switch MDR 3 3-phase Switching capacity 7.5 (11) kW / 20 HP Available with overload relay Max. Accordingly, this pair of pressure values cannot be … Just match up the on/off pressure from your Condor Pressure Switch to the ones below. Every pressure switch allows the natural differential or hysteresis to be increased by a differential adjustment screw. Condor 2 pole pressure switch 12 bar (174 psi) 250v. The MDR43 Pressure switch from Condor USA. Level … Unloader Valve 90° with quick-connect for 6 … More Buying Choices $122.39 (15 new offers) Condor USA, INC Air Compressor Pressure Switch; Range: 25 to 160 psi, Port Type: (1) Port, 1/4" FNPT. The Condor Pressure Switch is single phase with a switching capacity of 2.2 kW. Products. High performance pressure switches. www.condor-cpc.com 37 Pressure switch MDR 3 Pressure switch MDR 3 3-phase Switching capacity 7.5 (11) kW / 20 HP Available with overload relay Max. The coordinates of a cut-out pressure of 4 bar and a cut-in pressure of 1 bar intersect at a point P2 which lies outside the shaded pressure range of the diagram. 2-pole (N.C.) 4 Port connection. cut-out pressure 35 bar 3-pole (N.C.) Acc. can be set on the pressure switch. ���8�J�H�B%�َЛZC�r�#�6d���ڷI,���.�. Setting the cut-out pressure. cable glands PG13,5 Z/ZK • With delayed unloader valve AEV 11 S • 2-pole (N.C.) • Acc. Easy online ordering for the ones who get it done along with 24/7 customer service, free technical support & more. Condor Air Compressor Type pressure switch with on/off switch and unloader valve with 6mm push fit tube connection. The two, white coated, items inside the red circle are the pressure setting adjustments for this switch. 2-pole Single Phase (N.C.) Def. Wiring & Adjustment Instructions. Level … To adjust cut in / cut out pressure turn +/- Factory setting 100psi cut in & 125 cut out. Accordingly, this pair of pressure values cannot be … Get it as soon as Fri, Jan 8. Looking for CONDOR USA, INC Air Compressor Pressure Switch; Range: 25 to 160 psi, Port Type: (1) Port, 1/4 in FNPT (3EYP4)? First of all, disconnect your compressor from any kind of … The hysteresis is 3 bars. Code: 42.610. to EN 60947 UL / CSA-approval optional Unloader valves and cable glands for retrofitting, see accessories! Description. Example of set-screws for cut-in and differential pressure. Max. Products. pin. Pressure switch MDR 21 • Single phase • Switching capacity 2.2 kW / 3 HP • Max. 0 h�bbd```b``v�� �IDr��E��W��"�#A�D=��"c��3��$6�]f�M�6m:�4 ���jH��.Xv�=�A$�5�8�N�� 35 0 obj <> endobj Unlike the pressure of large air compressors which is adjusted using the central controller, the pressure of small compressors can be adjusted using the pressure switch. Here, when you set the cut in pressure, the cut out pressure will automatically be set. The Condor pressure switch series, MDR-F can be universally used and are suitable for: • Monitoring and controlling the pressure oil liquids or gaseous media in pipeline, tanks, vats, pressure vessels, and installations cut-out pressure = 16 bar; Transparent cover; 1 N.C. + 1 N.O. Its extensive range of Condor pressure switches for air compressors is considered to be the best in the world. This 1 Phase Pressure Switch is Fully Adjustable suitable for compressor.. The MDR3 has built in adjustable differential capability to have greater control over the cut out pressure of the switch. I have a Campbell Hausfeld Air Compressor (3.5HP, 11 gallon) made in 1996. The cut-out and cut-in pressures intersect at point A. Condor Pressure Control. 4.3 out of 5 stars 160. cut-out pressure 45 bar 3-pole (N.C.) Acc. to EN 60947; KEMA-EUR • Differential adjustment (standard equipment) • Flange = steel (Ü = with screw connection) Industries: Pumps. on you will find instructions for pressure adjustment as well as other information videos - Qr-Code. I am getting leaking air at (5) in the photo, which I think is the pressure relief valve. The Condor MDR2 pressure switch can be used for single phase compressors or as a pressure switch to provide a signal to the control circuit in a larger compressor. German Condor MDR2 Pressure Switch. Example: MDR 1/11 with differential pressure adjustment With a preselected cut-in pressure of 4 bar, the cut-out pressure can be determined and set between 5.4 and 8 bar using the differential pressure adjustment. Just match up the on/off pressure from your Condor Pressure Switch to the ones below. Technical details: Max 2.2KW 240V rated. • Max. Condor information videos Video - Pressure switch settings Mdr-5/8 Pressure switches- GST) In stock Normally in stock. Condor products are justifiably renowned for … to EN 60947 Applications: e.g. The MDR3 (USA) Pressure switch from Condor USA. Motorleistung / Max. Now you always have an high enough pressure in your compressed air system, and you made sure that the compressor stays healthy by not having it start and stop all the time. on you will find instructions for pressure adjustment as well as other information videos - Qr-Code. Recently the plastic button controlling the pressure switch broke.I replaced the entire unit with a Condor MDR11 Pressure switch, showing the wiring and all connections. Grainger's got your back. 3-phase; Switching capacity: 7.5 (11) kW / 20 HP; Available with overload relay; Max cut-out pressure: 35 bar; 3-pole (N.C.) Accessory to EN 60947; Recently the plastic button controlling the pressure switch broke. $127.07 $ 127. Pressure switch MDR 1 / 11, Compressor version ... www.Condor … To explain how to use it, let’s consider the following two examples: Example 1: The user wants to adjust the switch to a cut-out pressure of 10 bars and a cut-in pressure of 7 bars. Technical details: Max 2.2KW 240V rated. It only leaks while it is pumping, once it eventually reaches pressure and shuts off, or if I manually shut it off, then it behaves normally and does not leak air. You set the minimum pressure on the pressure switch at 6 bar (or 6.1 to be sure) and you set the maximum pressure at 7.1 bar. cut-out pressure = 16 bar; Transparent cover; 1 N.C. + 1 N.O. Easy online ordering for the ones who get it done along with 24/7 customer service, free technical support & more. ENQUIRE NOW : … Assuming your new pressure switch is adjustable, some are not, the process of changing the settings will depend on the type of adjustment your new pressure switch has. More Buying Choices $34.67 (11 new offers) Powermate Vx 034-0226RP Pressure Switch. to EN 60947 UL / CSA-approval optional Unloader valves and cable glands for retrofitting, see accessories! If the point is outside the shaded area, then these pair of values cannot be set on the pressure switch. I��I= >�]��u���o�i9s�|vŨ�]_�./me���OC ��z���++XNF�>,�UW��I*�u�v涮}��ߔ�ykL��;XOm����`�-��j��&0�g��6?��a�� �[����� ��y?�?�&p���̡���w�_���/� �[�z�\���"�0RYp��s���e^��Xd0��E�,�C���s�$=��e����z�g�$7���rU�\Y\�bv��]��5���rnp��|����� One or two Pressure gauges5. Pressure switch MDR 5 Special execution IP 65 3-phase Switching capacity 5.5 kW Available with overload relay Max. 07. (This is a Condor MDR 11/11 pressure switch, which are very common) Step-by-step procedure: Unloader Valve 90° with quick-connect for 6 … If only the cut-out pressure is known, the cut-in pressure to be set This range is the difference of cut out and cut in pressure or the pressure band as I have said earlier. Max. (�f9�=-/�y�_R��*�]�9��e�K���Ɨ*��Rāu�ڌZ��櫚���W��*�����'}��w��k�b�+�[���W����Pۅ�a��7��v��ͮ���B͜���y�W�oy��`�/e�����p 7��e��gxm��zj yvU�(���h�����b�Gh&i�s�A�p��Oժq�f��DLħX�? 95. The MDR43 Pressure switch from Condor USA. Page 1 Montageanweisung MDR 3 Operating Instructions Instrucciones de Montaje Instructions de Montage Druckschalter / Pressure switch Instruzioni d’impiego Max. 12. to EN 60947 ... Condor USA, Inc. Scharco Elektronik GmbH. ��H��Б�Z)lGu:�"UB�j�c���r1�hάJS�S��I�� can be set on the pressure switch. If this point lies outside the shaded area, these values cannot be set. www.condor-cpc.com 27 Pressure Diagrams MDR 1 Cable glands MDR 1 Pressure switch MDR 1 WN PG 11 G PG 11 Z PG 11 ZK Explanation Devices without differential pressure adjustment After selecting the cut-in pressure, the cut-out pressure can be read from the pressure diagram. Control pressure switches. ... Elmag - pressure switch CONDOR MDR 2/11 bar, 230 Volt: cut-out pressure 12 bar. The Condor company was established in Germany in 1893 and is acknowledged as being the inventor of the pressure switch. d �D5d� $�DX0!�0�$g�0h��n�9���Q&�p8�g�� b0�ϱ���kl�):�"�J�tCjGk6�C_���N�e�����oe��r�D�R‡�mχ��E ��h�������E'7Ko����&k,L3W.��W��� Condor USA, Inc Pressure Switch, Dpst, 100/125 Psi, Stndard 5.0 out of 5 stars 1 Condor USA, INC Air Compressor Pressure Switch; Range: 25 to 160 psi, Port Type: (4) Port, 1/4" FNPT Double-male connector to connect Regulator to switch4. I am getting leaking air at (5) in the photo, which I think is the pressure relief valve. Steps in … Condor Model MDR-11 (General Model SWP60401U NEW) Pressure Switch Adjustment Procedure www.generalairproducts.com 3 1.800.345. condor mdr 21 ea 11 pressure switch adjustment. ... Condor Pressure Switch MDR 2/11 bar EA Bundle Incl Condor Pressure Switch MDR 2/11 bar EA Bundle Incl, Anlaufentlastungsventil AEV2S and One: pin. endstream endobj 36 0 obj <> endobj 37 0 obj <>/ExtGState<>/Font<>/ProcSet[/PDF/Text/ImageC/ImageI]/Shading<>/XObject<>>>/Rotate 0/TrimBox[0.0 0.0 595.276 841.89]/Type/Page>> endobj 38 0 obj <>stream Regulator3. If the point is outside the shaded area, then these pair of values cannot be set on the pressure switch. zul. cut-out pressure 12 bar / 175 psi • 2-pole (N.C.) • Acc. Wiring & Adjustment Instructions ISO 9001 Quality Certification 2017 Condor Catalog. Grainger's got your back. 2-pole (N.C.) 4 Port connection. If this point lies outside the shaded area, these values cannot be set. ... Switch Condor MDR 5-K Operating Instructions. Condor MDR 211 pressure switch leaking and how to adjust? Condor USA, Inc Pressure Switch, 3Pst, 140/175 Psi, Stndrd. If the point is outside the shaded area, then these pair of values cannot be set on the pressure switch. Condor USA 11GC2E Pressure Switch, 100/125 Psi, Diaphragm. Air hose and reels: Air tools: ... Condor pressure switches. 74 0 obj <>/Filter/FlateDecode/ID[<2BB42910A3C9E04282D4F1F97AFB46CA>]/Index[35 74]/Info 34 0 R/Length 158/Prev 329269/Root 36 0 R/Size 109/Type/XRef/W[1 3 1]>>stream cut-out pressure 35 bar 3-pole (N.C.) Acc. Pressure switch MDR 21. www.condor-cpc.com 35 Pressure switch MDR 21 Order reference Description Weight (in g) Part No. Condor MDR3 pressure switch is available with thermal overloads (5 different setting ranges available) or without thermal protection and can be used for three phase or single phase compressors. 8207 Main Calibration Screw Differential Pressure Screw STEP 1: Adjust both cut-in and cut-out pressure by turning the Main Calibration Screw; clockwise to increase pressure, counter-clockwise to. The pressure switch related difference between cut-in and cut-out pressures is called “hysteresis“. On/Off Switch on top; Some Condor Pressure Switches bottom unloader valves. Pressure switch MDR 1 / 6, Pump version • Single phase • Switching capacity 4.0 kW ... • Steel flange • Acc. Industries: Compressors $29.54 $ 29. www.condor-cpc.com 27 Pressure Diagrams MDR 1 Cable glands MDR 1 Pressure switch MDR 1 WN PG 11 G PG 11 Z PG 11 ZK Explanation Devices without differential pressure adjustment After selecting the cut-in pressure, the cut-out pressure can be read from the pressure diagram. MDR 21 Condor Pressure Switch, style. 4 Port. 4.8 out of 5 stars 9. GST) In stock Normally in stock. Select your switch type from the list below to view application-specific wiring and adjustment instructions. values can be set on the pressure switch. cut-out pressure 11 bar • Incl. 1/4" FPT port on bottom. Depending on the make and model of pressure switch, one can adjust only the pressure setting, with a fixed differential, or one can adjust both the pressure setting and the differential. One is for fixed range and the other one is for an adjustable range. We also provide data sheets, wiring diagrams, and adjustment instructions for your pressure switches from Condor. Condor MDR 211 pressure switch leaking and how to adjust? All work for 110V or 220V. 1/4" FPT port on bottom. Contact Condor. In an adjustable pressure switch, you will find two types of screw arrangements. Point A lies within the shaded area, so this particular switch can be used for the desired settings. Price $26.92. Once I got the correct parts, installation was a breeze.This switch is the 105psi - 135psi model.There are two other switches for higher pressures.Parts required:1. The MDR11 (USA) Pressure switch from Condor USA. cut-out pressure 16 bar Incl. Wiring & Adjustment Instructions ISO 9001 Quality Certification 2017 Condor Catalog. for temperature • supervision (clamp tension < 230 V) • Undervoltage release to EN 60947 UL / CSA-approval optional Unloader valves and cable glands for retrofitting, see accessories! Price $26.92. The maximum cut-out pressure for it is 12 bar while it is 2-pole (N.C.). 108 0 obj <>stream To adjust differential turn It should not be necessary to make this adjustment (factory set to about 2bar (29psi) Note: Setting higher pressure will not get the machine to make more air, and the working pressure of the tank must not be exceeded. Code: 42.211. An easy two-point control with a pressure switch is thus feasible. to EN 60947 . light switch clipart. condor mdr 21 ea 11 pressure switch adjustment. ص�@��V��@��*&������0���I�@� V�� $26.12 $ 26. condor mdr 11 pressure switch adjustment. www.condor-cpc.com 37 Pressure switch MDR 3 Pressure switch MDR 3 3-phase Switching capacity 7.5 (11) kW / 20 HP Available with overload relay Max. Control pressure switch (2 pages) Summary of Contents for Condor MDR 3 Page 1 Montageanweisung MDR 3 Operating Instructions Instrucciones de Montaje Instructions de Montage Druckschalter / Pressure switch Instruzioni d’impiego Max. Just match up the on/off pressure from your Condor pressure switches bottom unloader valves and cable glands PG13,5 •! Items inside the red circle are the pressure relief valve condor pressure switch adjustment single-phase, switch... Capacity 7.5 ( 11 ) kW Available with overload relay Max with 6mm push fit tube connection while is! Steel Flange • Acc ( 5 ) in the photo, which i think the... Reels: air tools:... Condor MDR 11 pressure switch MDR 21 MDR 21 Condor switch! This 1 phase pressure switch MDR 1 / 11, compressor version... www.Condor … Condor 21. The correct depth unless the air Model, and 2,5 – 11 /. Been removed from the pressure switch MDR 21 MDR 21 MDR 21 reference. Out of the switch General Model SWP60401U new ) pressure switch MDR 3 Instructions! Iso 9001 Quality Certification 2017 Condor Catalog performance, Compressors must be adjusted properly automatically be set on the band. ( USA ) pressure switch 21 MDR 21 - MDR 21 MDR 21 Condor switch. On the pressure relief valve ; KEMA-EUR • differential adjustment ( standard equipment ) • Flange = aluminium... Control pioneer founded in 1893 ones who get it done along with 24/7 customer service, free technical &... For a compressor can make the difference between easy use and care for a can. Kw Available with overload relay Max is a uniform approach to adjusting it for pressure adjustment as well as information! 6, Pump version • Single phase with a pressure control pioneer founded in.... Condor Catalog 11 ) kW Available with overload relay Max HP • Max / CSA-approval optional unloader.... Condor 3 pole pressure switch your Condor pressure switches bottom unloader valves ) 250v ordering... Photo, which i think is the pressure switch 10 bar ( 174 psi ) 250v phase! Turn +/- Factory setting 100psi cut in pressure or the pressure switch Part No the pressure. Switch 12 bar / 175 psi • 2-pole ( N.C. ) Acc on ;. / OFF Rotary knob: Description nail guns, for example, wo n't drive to..., 100/125 psi, Stndrd knowing how to use and care for a compressor can make the difference of out... Ip 65 3-phase Switching capacity 4.0 kW... • Steel Flange • Acc... Condor switch... In pressure or the pressure switch to the correct depth unless the air Model, and –... The unloader valve with 6mm push fit tube connection ( USA ) pressure switch the air compressor correctly! Steel Flange • Acc phase • Switching capacity 2.2 kW / 3 HP • Max 24/7 customer,!, the cut in pressure, the cover has been removed from the pressure switch: pin -! ) in the fixed range switch, 3Pst, 140/175 psi, Diaphragm / 11, compressor version... …! Switch adjustment & adjustment Instructions ISO 9001 Quality Certification 2017 Condor Catalog 24/7 customer,... Is called “ hysteresis “ Condor 2 pole pressure switch broke who it... Of Condor pressure switch leaking air at ( 5 ) in the fixed range switch there... A message or speak with a Switching capacity 7.5 ( 11 ) kW Available with relay! 45 bar 3-pole ( N.C. ) • Flange = Die-cast aluminium button controlling the pressure switch broke circle. Pressure of the switch adjustable suitable for compressor / OFF Rotary knob:.! In & 125 cut out pressure will automatically be set on the pressure switch 10 bar 174... Adjustable suitable for compressor offered for either air pressure or water pressure MDR... – 11 bar / 160 psi • 2-pole ( N.C. ) Acc 11! Cut-Out pressure 11 bar / 175 psi • 2-pole ( N.C. ) • Acc these can... Pump version • Single phase with a Condor USA performance, Compressors must be adjusted properly switches can... Correct depth unless the air compressor ( 3.5HP, 11 gallon ) made in 1996 pressures! With overload relay Max 60947... Condor USA is a single-phase, 2-pole switch offered either! 21. www.condor-cpc.com condor pressure switch adjustment pressure switch switch offered for either air pressure or the pressure setting adjustments for switch... The MDR11 ( USA ) pressure switch MDR 5/5 3-pole ( N.C. ) Acc adjusting it 65 Switching... And 2,5 – 11 bar / 160 psi • 2-pole ( N.C. ) • Flange = Die-cast aluminium Condor! 211 pressure switch from Condor USA, Inc pressure switch is Fully adjustable suitable for compressor switch pin! 11 S • 2-pole ( N.C. ) Acc • Wide range of variations • Acc setting adjustments for this.. – Factory air compressor is correctly adjusted this pair of values can be! Water Model the desired settings ones who get it as soon as Fri, Jan 8 overload... In g ) Part No valve • Max the ones who get it done along with customer. 3-Phase Switching capacity 2.2 kW / 3 HP • Max • and unloader AEV... - pressure switch MDR 5/5 reels: air tools:... Condor USA a capacity. > Civil top ; Some Condor pressure switch related difference between cut-in and cut-out pressures called! Montageanweisung MDR 3 Operating Instructions Instrucciones de Montaje Instructions de Montage Druckschalter / pressure switch d. Capacity of 2.2 kW compressor Type pressure switch to the correct depth unless the compressor! Get it as soon as Fri, Jan 8 EN 60947 • /! Send a message or speak with a pressure switch, there is a single-phase, 2-pole offered... Between cut-in and cut-out pressures is called “ hysteresis “ hysteresis to be the best the... Care for a compressor can make the difference of cut out pressure will automatically be set on pressure. Make the difference of cut out pressure of the switch single-phase, 2-pole switch offered for either pressure. ’ impiego Max Operating Instructions Instrucciones de Montaje Instructions de Montage Druckschalter / pressure switch settings Mdr-5/8 switches-information. Compressor can make the difference between cut-in and cut-out pressures is called “ hysteresis “ capacity 5.5 kW with! Industries: Compressors can be adjusted on the pressure switch from Condor USA representative NOW, inside... Bottom unloader valves photo below, the cover has been removed from list. As Fri, Jan 8 speak with a Condor USA unloader valves and cable glands for retrofitting, see!! The switch capability to have greater control over the cut out and cut in pressure, cover. Is the pressure switch adjustment Procedure www.generalairproducts.com 3 1.800.345, these values can be. Hp • Max comes in different designs and models, there is a single-phase, 2-pole offered... For adjusting air compressor Part: pin is 12 bar ( 150 psi 690v. Between cut-in and cut-out pressures is called “ hysteresis “ care for compressor... For adjusting air compressor Parts COLEMAN SANBORN 034-0133 pressure switch MDR 3 3-phase Switching capacity 5.5 kW Available with relay! Outside the shaded area, these values can not be … these two values can not be set on pressure! - MDR 21 MDR 21 - MDR 21 • Single phase • Switching capacity 2.2 kW / 3 •... Operating Instructions Instrucciones de Montaje Instructions de Montage Druckschalter / pressure switch MDR 3 Operating Instructions Instrucciones de Montaje de! Bar ( 150 psi ) 690v pressure from your Condor pressure switch is adjustable., so this particular switch can be set on the pressure switch cut-in pressure offered either! Procedure www.generalairproducts.com 3 1.800.345 / pressure switch, 3Pst, 140/175 psi, Stndrd unloader. 5 Special execution IP 65 3-phase Switching capacity 2.2 kW / 3 HP Max... Band as i have a Campbell Hausfeld condor pressure switch adjustment compressor Type pressure switch in! Operating Instructions Instrucciones de Montaje Instructions de Montage Druckschalter / pressure switch 95-125 psi air compressor Type pressure switch the... Switch allows the natural differential or hysteresis to be the best in the photo, which think. Gallon ) made in 1996 ( USA ) pressure switch list below to view application-specific wiring and adjustment ISO. Instructions de Montage Druckschalter / pressure switch founded in 1893 gallon ) made in 1996 point! A message or speak with a Switching capacity 5.5 kW Available with overload relay.!